Oxygen Not Included Best Way to Make Oxygen: SPOM Guide
Oxygen Not Included best way to make oxygen: compare diffusers and electrolyzers, build a SPOM, and manage water, heat, and airflow to keep colonies alive.
Jump to

What Is the Best Way to Produce Oxygen?
The answer to “Oxygen Not Included best way to make oxygen” depends on your resources: start with an oxygen diffuser when algae is available, then transition to an electrolyzer supplied by renewable water. Collect hydrogen in a self-powered oxygen machine (SPOM). One electrolyzer produces 888 g/s of oxygen, enough for eight standard Duplicants with some headroom.
The important distinction is oxygen produced versus oxygen delivered. Adding electrolyzers will not help if your pumps cannot remove their output or your pipes cannot carry it into the base.
| Oxygen setup | Maximum oxygen output delivered | Main limitation |
|---|---|---|
| One oxygen diffuser | 500 g/s | Algae supply and surrounding gas pressure |
| One electrolyzer with two oxygen pumps | 888 g/s | Electrolyzer output |
| Two electrolyzers with two oxygen pumps | 1,000 g/s | Oxygen pump capacity |
| Half Rodriguez: two electrolyzers, four oxygen pumps | 1,776 g/s | Electrolyzer output |
| Full Rodriguez: four electrolyzers, six oxygen pumps | 3,000 g/s | Oxygen pump capacity |
These electrolyzer setups also need hydrogen collection and separation. The pump counts in the table refer only to pumps moving oxygen.
Official page: Oxygen Not Included (klei.com)
Use an Oxygen Diffuser to Stabilize the Early Game
On Terra, nearby algae makes the oxygen diffuser a straightforward starting option. Connect it to a manual generator and battery, keep algae deliveries available, and give its output room to spread.

A diffuser consumes 550 g/s of algae while producing 500 g/s of oxygen. A standard Duplicant consumes 100 g/s, so one continuously operating diffuser matches the breathing demand of five standard Duplicants. That leaves no production margin at five, and interrupted deliveries or power shortages reduce its actual output.
Place the diffuser near connected living spaces rather than inside a cramped utility closet. Local pressure can stop production while distant bedrooms remain short of oxygen.
To improve circulation:
- Leave space beside ladders so gases can move through vertical shafts.
- Use airflow tiles where solid floors block gas movement.
- Give carbon dioxide a route toward the bottom of the base.
- Check the oxygen overlay in occupied rooms, not just around the diffuser.
Starting oxylite buys time while you build this equipment, but it is a temporary reserve. Nearby algae is also finite unless you establish additional production. Begin preparing your water-based system while the diffuser still has fuel.
Hold off on printing more Duplicants when oxygen production is already stretched. Mouth Breather Duplicants increase demand, so include their higher consumption when judging whether your equipment can support another arrival.
Secure Enough Water Before Switching to Electrolyzers
An electrolyzer consumes 1,000 g/s of clean water and 120 W while operating at full capacity. It produces:

- 888 g/s of oxygen
- 112 g/s of hydrogen
Water delivery directly determines production. Supplying only 500 g/s of water reduces oxygen output to 444 g/s. Building more electrolyzers cannot compensate for an inadequate water supply.
Analyze vents and geysers before committing their output to oxygen production. Use their average output across the full activity and dormancy cycle when budgeting water. A vent averaging 458.8 g/s cannot continuously supply even one electrolyzer at half capacity without another source contributing.
Store water to bridge dormancy periods, but distinguish storage from sustainability. A large reservoir can conceal a long-term deficit until it empties.
For planning, reserve one fully supplied electrolyzer for eight standard Duplicants. Its theoretical breathing capacity is 8.88, but planning around eight leaves room for interruptions and changing demand.
Keep your diffuser available during the transition. Remove the old supply only after the new system delivers oxygen reliably to the rooms where Duplicants actually breathe.
Build and Start a Self-Powered Oxygen Machine
A SPOM uses the electrolyzer’s hydrogen to fuel hydrogen generators, which power the oxygen equipment. Its core components are electrolyzers, gas pumps, hydrogen generators, a smart battery, and automation.

Hydrogen rises above oxygen, allowing a suitable chamber layout to separate the gases. Pressure-controlled pumps preserve that separation while moving each gas into its own pipe.
Plan the chamber around gas movement
Place hydrogen collection above the electrolyzers and oxygen collection below them. Use a proven chamber layout when building your first system: pump positions, internal spaces, and sensor placement all affect whether the hydrogen layer stays stable.
Common Rodriguez-style settings are:
| Control | Setting |
|---|---|
| Hydrogen pump atmo sensor | Above 250 g |
| Oxygen pump atmo sensors | Above 450 g |
| Smart battery low threshold | 60% |
| Smart battery high threshold | 90 |
Treat those pressure values as settings for that layout. Other chamber shapes use different thresholds, including 600 g for oxygen collection.
Connect the smart battery to the hydrogen generators with automation wire. This stops them from burning fuel continuously when the battery is already charged.
Prime the system before feeding the generators
The upper pump will initially collect whatever gas already occupies the chamber. Sending that mixture directly into a hydrogen generator causes damage when oxygen or another unwanted gas arrives.
Start the system in this order:
- Provide external startup power. Use a manual generator or a suitable connection to the colony’s power grid.
- Divert the hydrogen collection pipe into a gas reservoir. Keep its initial contents away from the hydrogen generators.
- Keep the oxygen outlets flowing. Backed-up oxygen prevents the chamber from establishing its intended gas layers.
- Wait for a stable hydrogen layer. Inspect the upper pump’s pipe until it carries a continuous hydrogen stream.
- Clear the startup gas from the generator supply route. Reconnect only after the line feeding the generators contains hydrogen.
- Let hydrogen power take over. Confirm that the battery charges and oxygen delivery continues before removing startup power.
Watch the temporary reservoir during priming. If it fills, provide more collection capacity so the upper pump can keep clearing unwanted gas.
Provide a hydrogen overflow
A full hydrogen line can obstruct gas removal and disrupt the system. Give surplus hydrogen an overflow route to storage or another hydrogen generator.
Prioritize the generators that keep the oxygen equipment running, then send the excess elsewhere. Otherwise, an unrelated power demand can consume the fuel your oxygen system needs.
Keep a way to restart the SPOM after a long shutdown. Smart batteries lose charge over time, so a system that remains idle long enough can need external power again.
Match Pumps and Pipes to the Colony
A gas pump moves 500 g/s, while a gas pipe carries 1,000 g/s. Those limits explain why similarly sized oxygen machines can support different populations.
Two electrolyzers can produce 1,776 g/s of oxygen, but two oxygen pumps can extract only 1,000 g/s. That setup supplies the standard breathing demand of ten Duplicants, regardless of how much production capacity sits above the pumps.
A half Rodriguez uses four oxygen pumps for two electrolyzers. Its pump capacity exceeds the electrolyzers’ output, allowing the system to deliver the full 1,776 g/s when supplied and operating correctly.
The standard full Rodriguez has a different bottleneck. Four electrolyzers could produce 3,552 g/s, but six oxygen pumps move only 3,000 g/s—enough to match thirty standard Duplicants’ breathing demand.
When expanding:
- Add pumping capacity where extraction is the bottleneck.
- Split oxygen across separate pipe routes before exceeding one pipe’s capacity.
- Check water availability before adding electrolyzers.
- Leave production margin rather than matching theoretical demand exactly.
Separating two pumps onto individual pipes does not increase either pump’s output. Each still moves only 500 g/s.
Control Heat Before It Reaches Your Farms
Electrolyzers produce gas at at least 70°C, or hotter when their input water is hotter. Cool starting terrain can temporarily absorb that heat, making an early setup look safer than it will be after prolonged operation.
Build the oxygen machinery away from temperature-sensitive crops and insulate the chamber. Bristle Blossoms are vulnerable when temperatures rise above 30°C, so routing hot oxygen through farms can turn a breathing solution into a food shortage.
Use insulated pipes to limit unwanted heat transfer along the water supply. Where cooling is needed, route oxygen through a cooling area before distributing it into occupied spaces.
Equipment materials matter inside an insulated chamber:
- Gold amalgam adds 50°C to a building’s overheat temperature.
- A gold amalgam hydrogen generator has a 125°C overheat threshold.
- A steel hydrogen generator has a 275°C overheat threshold.
Use appropriate materials for electrolyzers, pumps, and generators rather than assuming ordinary metal equipment will survive indefinitely.
Insulation contains heat; it does not remove it. Running hydrogen through radiant gas pipes around the generators transfers some equipment heat into gas that will be consumed. Oxygen cooling still needs its own provision when the outgoing gas would overheat the base. Larger systems can use a thermo aquatuner and steam turbine cooling loop.
Diagnose Low Oxygen Before Adding More Machines
Open the oxygen overlay and follow the problem from production to the affected room.
If the machine is idle, inspect its inputs. Check power, algae deliveries, clean-water flow, and automation. An electrolyzer receiving intermittent water cannot maintain its rated output.
If the machine reports overpressure, inspect its surroundings and outlets. A diffuser can become locally blocked inside a small room. A SPOM can stop because its oxygen pipes are full or its destination vents cannot release gas.
If some rooms breathe well and others do not, improve circulation. Widen obstructed shafts and add airflow tiles where floors isolate rooms. Carbon dioxide collecting in lower areas can displace breathable gas even while oxygen remains plentiful elsewhere.
Aim for roughly 1–2 kg of oxygen per tile in occupied areas. Avoid pushing living spaces above 4 kg per tile, where Duplicants can suffer popped eardrums.
Use normal gas vents for routine base distribution. High-pressure vents used to keep outlets flowing during startup need careful attention; replace temporary ones before leaving the system to fill living areas.
A SPOM pausing because the base has enough oxygen is expected behavior. When the delivery pipes fill, pumps stop, chamber pressure rises, and electrolyzers stop consuming water. Investigate when oxygen is scarce where Duplicants need it, rather than treating every production pause as a fault.
Use Alternative Oxygen Methods Where Their Resources Fit
Algae and renewable water are not equally accessible on every asteroid. Other methods can bridge a shortage or take advantage of local resources.
Deodorizers and polluted oxygen
Deodorizers convert polluted oxygen into clean oxygen. Position them along routes where polluted oxygen enters the base, with airflow tiles underneath when a solid floor would restrict circulation.
Polluted oxygen is breathable, but it causes Yucky Lungs, increasing oxygen consumption. Clean it before relying on it for occupied areas.
Opening an existing polluted-oxygen pocket provides a finite reserve. Keep developing a continuing supply while that reserve buys construction time.
Algae terrariums
An algae terrarium produces 40 g/s of oxygen, increasing to 44 g/s when lit, and consumes 300 g/s of water. It needs no electrical power and removes a small amount of carbon dioxide.
Its main cost is Duplicant labor: water and algae need delivery, and polluted water needs removal. Place terrariums near a pitcher pump to reduce hauling.
Use them for temporary breathing pockets in remote work areas or when early power is restricted. Avoid building a large terrarium dependency without accounting for the delivery workload.
Oxyferns
Oxyferns consume carbon dioxide and release oxygen. Wild plants require no supplied resources, while domesticated plants increase production at the cost of 19 kg of water and 4 kg of dirt per cycle per plant.
Place them where carbon dioxide collects. A plant isolated above the colony receives little benefit from the carbon dioxide settling below it.
Pips can replant oxyferns while preserving their wild status. Domestication supplies more oxygen from the plants available, but adds ongoing resource and labor costs.
Rust deoxidizers
A rust deoxidizer consumes 750 g/s of rust, 250 g/s of salt, and 60 W. It produces 570 g/s of oxygen, 30 g/s of chlorine, and 400 g/s of iron ore.
Use this option when the asteroid provides rust and salt. Contain the machinery, separate the chlorine from the breathable output, and manage the hot gas before routing oxygen toward farms. Keep the chlorine collection route clear so it cannot spread into the colony’s living spaces.
Continue with
Oxygen Not Included Hydra: Build and Startup GuideBuild an Oxygen Not Included hydra with reliable gas separation, pressure controls, and cooling. Learn water requirements and fix common startup problems.Join the community
Official channels for news, updates and player help:
